Ampatex® LDA 0.02 plus - Renovation Vapour check
What is it and why is it changing how we upgrade older homes?
We are used to seeing SD values in airtight membranes – LDA is different in that it lists an a value – 0.004m3/(h*m2). The a value describes the quantity of air passing through the layer. (The SD vale relates to the humidity or vapour). While the a value is not currently a defined standard the reference value in the industry for an airtight layer is <0.01m3/m2/h.
This solution starts with higher humiditys and the quality of application is (As it is with all VCL’s) important. To assist with this AMPACK have include integrated tapes on both sides of the membrane and has the same incredible strength we have become accustomed to from AMPACKs exterior membranes.
When we consider quality of application is is important to understand why – a 1mm wide gap can allow 360g water per day – such errors can create issues in any VCL system and as always we recommend a blower door test. In this case it should be carried out when LDA has been installed and before the windtight membrane (PROTECTA is installed).